Obraz może przedstawiać obraz.
Szczegóły produktu można znaleźć w specyfikacjach.
RE46C100S8TF

RE46C100S8TF

Product Overview

Category

RE46C100S8TF belongs to the category of integrated circuits (ICs).

Use

This product is primarily used for fire detection and alarm systems.

Characteristics

  • Integrated circuit designed for fire detection applications
  • High sensitivity to smoke particles
  • Low power consumption
  • Compact size for easy integration into various devices

Package

RE46C100S8TF is available in a small outline package (SOP) format.

Essence

The essence of this product lies in its ability to detect smoke particles and trigger an alarm in fire detection systems.

Packaging/Quantity

RE46C100S8TF is typically packaged in reels, with a quantity of 2500 units per reel.

Specifications

  • Supply Voltage: 2.7V to 5.5V
  • Operating Temperature Range: -40°C to +85°C
  • Smoke Detection Sensitivity: Adjustable through external components
  • Alarm Output: Active-low signal
  • Standby Current: 1µA (typical)
  • Response Time: Less than 10 seconds

Detailed Pin Configuration

  1. VDD: Power supply input
  2. GND: Ground reference
  3. SENSE+: Positive terminal of the smoke sensing chamber
  4. SENSE-: Negative terminal of the smoke sensing chamber
  5. TEST: Test mode input
  6. ALARM: Active-low alarm output
  7. NC: No connection
  8. NC: No connection

Functional Features

  • Smoke Sensing: The RE46C100S8TF utilizes a specialized chamber to detect smoke particles.
  • Adjustable Sensitivity: The sensitivity of the smoke detection can be adjusted using external components.
  • Alarm Output: When smoke is detected, the active-low alarm output is triggered.
  • Test Mode: The test mode input allows for easy verification of the circuit's functionality.

Advantages and Disadvantages

Advantages

  • High sensitivity to smoke particles ensures reliable fire detection.
  • Low power consumption makes it suitable for battery-powered applications.
  • Compact size enables easy integration into various devices.

Disadvantages

  • Requires external components for adjusting sensitivity.
  • Limited to smoke detection and alarm functionality.

Working Principles

The RE46C100S8TF operates on the principle of smoke particle detection. It utilizes a specialized chamber where smoke particles are detected. When smoke is present, the circuit triggers an alarm output, indicating the presence of a potential fire hazard.

Detailed Application Field Plans

The RE46C100S8TF is widely used in various fire detection and alarm systems, including:

  1. Residential buildings: Installed in homes and apartments to provide early warning in case of fire.
  2. Commercial establishments: Used in offices, hotels, shopping malls, and other commercial spaces to ensure the safety of occupants.
  3. Industrial facilities: Integrated into factories, warehouses, and manufacturing plants to detect fires and prevent potential disasters.
  4. Public spaces: Deployed in public buildings, schools, hospitals, and airports to enhance fire safety measures.

Detailed and Complete Alternative Models

  1. RE46C100S8T: Similar to RE46C100S8TF, but without the adjustable smoke detection sensitivity feature.
  2. RE46C100S8TG: Enhanced version with additional built-in self-test capabilities for improved reliability.
  3. RE46C100S8TH: Higher sensitivity variant designed for applications requiring ultra-sensitive smoke detection.

These alternative models offer different features and specifications to cater to specific requirements in fire detection systems.

Word count: 455 words

Wymień 10 typowych pytań i odpowiedzi związanych z zastosowaniem RE46C100S8TF w rozwiązaniach technicznych

  1. What is the RE46C100S8TF?
    The RE46C100S8TF is a low-power, CMOS photoelectric smoke detector IC.

  2. How does the RE46C100S8TF work?
    The RE46C100S8TF uses an integrated photodiode and amplifier to detect smoke particles in the air, triggering an alarm when smoke is detected.

  3. What is the operating voltage range of the RE46C100S8TF?
    The operating voltage range of the RE46C100S8TF is typically 2.7V to 6.0V.

  4. Can the RE46C100S8TF be used in battery-powered applications?
    Yes, the low-power consumption of the RE46C100S8TF makes it suitable for battery-powered applications.

  5. What is the typical response time of the RE46C100S8TF?
    The typical response time of the RE46C100S8TF is less than 10 seconds in the presence of smoke.

  6. Is the RE46C100S8TF suitable for use in residential smoke detectors?
    Yes, the RE46C100S8TF is designed for use in residential smoke detectors and complies with relevant safety standards.

  7. Does the RE46C100S8TF have built-in self-test features?
    Yes, the RE46C100S8TF includes self-test circuitry to ensure proper operation.

  8. Can the RE46C100S8TF be used in conjunction with other sensors?
    Yes, the RE46C100S8TF can be integrated with other sensors for enhanced fire detection systems.

  9. What is the recommended operating temperature range for the RE46C100S8TF?
    The recommended operating temperature range for the RE46C100S8TF is -20°C to 70°C.

  10. Are there any application notes or reference designs available for the RE46C100S8TF?
    Yes, application notes and reference designs are available to assist in the implementation of the RE46C100S8TF in technical solutions.