Obraz może przedstawiać obraz.
Szczegóły produktu można znaleźć w specyfikacjach.
T6613-5KF

T6613-5KF Product Overview

1. Introduction

The T6613-5KF is a sensor module designed for measuring carbon dioxide (CO2) levels in various applications. This entry provides a comprehensive overview of the T6613-5KF, including its product category, basic information, specifications, pin configuration, functional features, advantages and disadvantages, working principles, application field plans, and alternative models.

2. Basic Information Overview

  • Category: Gas Sensor Module
  • Use: Measurement of Carbon Dioxide (CO2) Levels
  • Characteristics: High Accuracy, Low Power Consumption, Compact Design
  • Package Essence: Sensor Module with Integrated CO2 Sensing Element
  • Packaging/Quantity: Typically Packaged as Individual Modules

3. Specifications

  • Measurement Range: 0-5000 ppm
  • Accuracy: ±50 ppm ±3% of reading
  • Operating Voltage: 3.6V to 5.5V
  • Output Interface: I2C or UART
  • Operating Temperature: -20°C to 70°C
  • Storage Temperature: -40°C to 85°C

4. Detailed Pin Configuration

The T6613-5KF sensor module typically features the following pin configuration: - VCC: Power Supply Input - GND: Ground Connection - SDA: I2C Data Line - SCL: I2C Clock Line - TXD: UART Transmit Data - RXD: UART Receive Data

5. Functional Features

  • High Accuracy: Provides precise CO2 level measurements.
  • Low Power Consumption: Suitable for battery-powered applications.
  • Compact Design: Enables integration into various devices and systems.

6. Advantages and Disadvantages

Advantages

  • Accurate CO2 measurement
  • Low power consumption
  • Compact design for easy integration

Disadvantages

  • Limited operating temperature range
  • Requires additional calibration for specific applications

7. Working Principles

The T6613-5KF utilizes non-dispersive infrared (NDIR) technology to measure CO2 levels. It operates by emitting infrared light through the gas sample and detecting the absorption of this light by CO2 molecules. The amount of absorbed light is then correlated to the CO2 concentration, providing an accurate measurement.

8. Detailed Application Field Plans

The T6613-5KF sensor module finds applications in various fields, including: - Indoor Air Quality Monitoring - HVAC Systems - Automotive Cabin Air Quality Monitoring - Industrial Safety and Environmental Monitoring

9. Detailed and Complete Alternative Models

Some alternative models to the T6613-5KF sensor module include: - T6615-5KF: Similar CO2 sensor module with extended measurement range - T6713-5KF: Enhanced CO2 sensor module with additional environmental sensing capabilities

In conclusion, the T6613-5KF sensor module offers high accuracy and low power consumption, making it suitable for diverse CO2 measurement applications across different industries.

[Word Count: 410]

Wymień 10 typowych pytań i odpowiedzi związanych z zastosowaniem T6613-5KF w rozwiązaniach technicznych

Sure, here are 10 common questions and answers related to the application of T6613-5KF in technical solutions:

  1. Q: What is T6613-5KF? A: T6613-5KF is a specific model of gas sensor designed for measuring carbon dioxide (CO2) levels in various technical applications.

  2. Q: What are the typical technical solutions where T6613-5KF is used? A: T6613-5KF is commonly used in HVAC systems, indoor air quality monitoring, industrial process control, and environmental monitoring applications.

  3. Q: How does T6613-5KF measure CO2 levels? A: T6613-5KF uses non-dispersive infrared (NDIR) technology to measure the concentration of CO2 in the surrounding air.

  4. Q: What is the measurement range of T6613-5KF? A: The measurement range of T6613-5KF typically spans from 0 to 5000 parts per million (ppm) of CO2.

  5. Q: Can T6613-5KF be integrated with existing control systems? A: Yes, T6613-5KF is designed to be compatible with various control systems and can be easily integrated into existing technical solutions.

  6. Q: What are the power requirements for T6613-5KF? A: T6613-5KF typically operates on a low voltage DC power supply, making it suitable for a wide range of technical applications.

  7. Q: Is T6613-5KF suitable for outdoor use? A: T6613-5KF is primarily designed for indoor use, but with proper protection from environmental elements, it can also be used in outdoor applications.

  8. Q: How often does T6613-5KF require calibration? A: T6613-5KF generally requires periodic calibration to ensure accurate CO2 measurements, typically recommended every 12 to 18 months.

  9. Q: Can T6613-5KF provide real-time CO2 level data? A: Yes, T6613-5KF is capable of providing real-time CO2 level data, allowing for continuous monitoring and control of CO2 levels in technical solutions.

  10. Q: Are there any special considerations for installing T6613-5KF in technical solutions? A: It is important to install T6613-5KF in a location that represents the average CO2 concentration of the area being monitored, away from direct airflow or sources of contamination, to ensure accurate measurements.